Circuit Breakers
Protective devices that interrupt current flow when faults are detected
Available Brands
SUSOL PHL3
Fixed pad-lock devices for Susol MCCB TS400U, locking in the on and off position Please download the LS Susol Catalog linked below for full product details.
SUSOL MIT43
Mechanical interlocking device for Susol MCCB TS800U, padlocks are not suplied Please download the LS Susol Catalog linked below for full product details
SUSOL MIT13
Mechanical interlocking device for Susol MCCB TD125U, padlocks are not suplied Please download the LS Susol Catalog linked below for full product details.
SUSOL MIT33
Mechanical interlocking device for Susol MCCB TS400U, padlocks are not suplied Please download the LS Susol Catalog linked below for full product details.
SUSOL MIT23
Mechanical interlocking device for Susol MCCB TS250U, padlocks are not suplied Please download the LS Susol Catalog linked below for full product details.
UTS600N FTU 500 3LLUL
500A LS Susol MCCB, 600AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS600N FTU 600 3LLUL
600A LS Susol MCCB, 600AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS600N FMU 600 3LLUL
600A LS Susol MCCB, 600AF, 3 Pole, with a Adjustable Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS600N FMU 500 3LLUL
500A LS Susol MCCB, 600AF, 3 Pole, with a Adjustable Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS600N ATU 500 3LLUL
500A LS Susol MCCB, 600AF, 3 Pole, with a Adjustable Thermal & a Adjustable Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS600N ATU 600 3LLUL
600A LS Susol MCCB, 600AF, 3 Pole, with a Adjustable Thermal & a Adjustable Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS600H FTU 500 3LLUL
500A LS Susol MCCB, 600AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 100kA@240VAC, 65kA@480VAC, 35kA@600VAC, UL Approved
UTS600H FTU 600 3LLUL
600A LS Susol MCCB, 600AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 100kA@240VAC, 65kA@480VAC, 35kA@600VAC, UL Approved
UTS600H FMU 500 3LLUL
500A LS Susol MCCB, 600AF, 3 Pole, with a Adjustable Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 100kA@240VAC, 65kA@480VAC, 35kA@600VAC, UL Approved
UTS600H FMU 600 3LLUL
600A LS Susol MCCB, 600AF, 3 Pole, with a Adjustable Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 100kA@240VAC, 65kA@480VAC, 35kA@600VAC, UL Approved
UTS600H ATU 500 3LLUL
500A LS Susol MCCB, 600AF, 3 Pole, with a Adjustable Thermal & a Adjustable Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 100kA@240VAC, 65kA@480VAC, 35kA@600VAC, UL Approved
UTS600L FTU 500 3LLUL
500A LS Susol MCCB, 600AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 150kA@240VAC, 100kA@480VAC, 50kA@600VAC, UL Approved
UTS600H ATU 600 3LLUL
600A LS Susol MCCB, 600AF, 3 Pole, with a Adjustable Thermal & a Adjustable Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 100kA@240VAC, 65kA@480VAC, 35kA@600VAC, UL Approved
UTS600L FTU 600 3LLUL
600A LS Susol MCCB, 600AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 150kA@240VAC, 100kA@480VAC, 50kA@600VAC, UL Approved
UTS600L FMU 500 3LLUL
500A LS Susol MCCB, 600AF, 3 Pole, with a Adjustable Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 150kA@240VAC, 100kA@480VAC, 50kA@600VAC, UL Approved
UTS600L FMU 600 3LLUL
600A LS Susol MCCB, 600AF, 3 Pole, with a Adjustable Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 150kA@240VAC, 100kA@480VAC, 50kA@600VAC, UL Approved
UTS600L ATU 500 3LLUL
500A LS Susol MCCB, 600AF, 3 Pole, with a Adjustable Thermal & a Adjustable Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 150kA@240VAC, 100kA@480VAC, 50kA@600VAC, UL Approved
UTS600L ATU 600 3LLUL
600A LS Susol MCCB, 600AF, 3 Pole, with a Adjustable Thermal & a Adjustable Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 150kA@240VAC, 100kA@480VAC, 50kA@600VAC, UL Approved
UTS600L MCS 600 3LLUL
600A LS Susol MCCB, 600AF, 3 Pole, with a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performace 150kA@240VAC, 100kA@480VAC, 50kA@600VAC, UL Approved
Related Product Types
You might also be interested in these product categories
Variable Frequency Drives
Motor speed control drives for precise control of AC motor speed and torque
Miniature Circuit Breakers
Compact circuit breakers for residential and commercial applications
Motor Circuit Protectors
Specialized protection devices for motor circuits and applications
Contactors
Electromagnetic switches for controlling electrical circuits
Overload Relays
Protective devices that monitor motor current and prevent overload damage
Programmable Logic Controllers
Industrial computers for automation and control systems