Circuit Breakers
Protective devices that interrupt current flow when faults are detected
Available Brands
UTS150L MCP 150 3LLUL
150A LS Susol MCCB, 150AF, 3 Pole, with a Adjustable Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performance 150kA@240VAC, 100kA@480VAC, 50kA@600VAC, UL Approved
UTS150L MCS 150 3LLUL
150A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, Rated Performance 150kA@240VAC, 100kA@480VAC, 50kA@600VAC, UL Approved
UTS150NT FTU 50 3LLUL
50A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150NT FTU 40 3LLUL
40A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150NT FTU 60 3LLUL
60A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150NT FTU 70 3LLUL
70A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150NT FTU 90 3LLUL
90A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150NT FTU 80 3LLUL
80A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150NT FTU 100 3LLUL
100A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150NT FTU 125 3LLUL
125A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150NT FTU 150 3LLUL
150A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150NT FMU 40 3LLUL
40A LS Susol MCCB, 150AF, 3 Pole, with a Adjustable Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150NT FMU 60 3LLUL
60A LS Susol MCCB, 150AF, 3 Pole, with a Adjustable Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150NT FMU 80 3LLUL
80A LS Susol MCCB, 150AF, 3 Pole, with a Adjustable Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150NT FMU 100 3LLUL
100A LS Susol MCCB, 150AF, 3 Pole, with a Adjustable Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150NT FMU 150 3LLUL
150A LS Susol MCCB, 150AF, 3 Pole, with a Adjustable Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150NT ATU 100 3LLUL
100A LS Susol MCCB, 150AF, 3 Pole, with a Adjustable Thermal & a Adjustable Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150HT FTU 40 3LLUL
40A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 100kA@240VAC, 65kA@480VAC, 35kA@600VAC, UL Approved
UTS150NT ATU 150 3LLUL
150A LS Susol MCCB, 150AF, 3 Pole, with a Adjustable Thermal & a Adjustable Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 65kA@240VAC, 35kA@480VAC, 18kA@600VAC, UL Approved
UTS150HT FTU 50 3LLUL
50A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 100kA@240VAC, 65kA@480VAC, 35kA@600VAC, UL Approved
UTS150HT FTU 60 3LLUL
60A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 100kA@240VAC, 65kA@480VAC, 35kA@600VAC, UL Approved
UTS150HT FTU 70 3LLUL
70A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 100kA@240VAC, 65kA@480VAC, 35kA@600VAC, UL Approved
UTS150HT FTU 80 3LLUL
80A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 100kA@240VAC, 65kA@480VAC, 35kA@600VAC, UL Approved
UTS150HT FTU 90 3LLUL
90A LS Susol MCCB, 150AF, 3 Pole, with a Fixed Thermal & a Fixed Magnetic Trip Unit, Lugs Line/ Load Side, 100% Rated Performance 100kA@240VAC, 65kA@480VAC, 35kA@600VAC, UL Approved
Related Product Types
You might also be interested in these product categories
Variable Frequency Drives
Motor speed control drives for precise control of AC motor speed and torque
Miniature Circuit Breakers
Compact circuit breakers for residential and commercial applications
Motor Circuit Protectors
Specialized protection devices for motor circuits and applications
Contactors
Electromagnetic switches for controlling electrical circuits
Overload Relays
Protective devices that monitor motor current and prevent overload damage