Showing all 9 results

  • medium voltage VFD

    Medium Voltage VFD

    0 out of 5
    • Compact size
    • Energy saving & high efficiency
    • Redundant cell poweer factor control
    • Built-in cell bypass

    pdf icon smallMedium Voltage VFD Catalogue (3.7 MB)

     


    Read more
  • LS-starvert-ic5

    Starvert iC5

    0 out of 5
    • Powerful & compact sensorless vector control VFD
    • 1 phase 0.1~2.2 kW (0.5~3HP), 200~230V
    • Selectable V/F, Sensorless vector control
    • Motor parameter auto-tuning
    • Powerful torque at overall speed range
    • IP20 enclosure
    • Built-in potentiometer
    • Optional Modbus RTU Communication

    Specificationspdf icon small

     


    Read more
  • starvert-ie5

    Starvert iE5

    0 out of 5
    • User friendly micro size slim VFD
    • 1 phase 0.1~0.4kW (1~0.5HP), 200~230V
    • 3 phase 0.1~0.4kW (1~0.5HP), 200~230V
    • V/F Control
    • Compact size : 68 x 128 x 85mm (2.7 x 5 x 3.3 inch)
    • 0.1 ~ 200 Hz frequency output
    • 1 ~ 10 khz carrier frequency
    • Fault history : last 3 faults
    • 1 P20 Enclosure
    • RS485 (LS BUS/Modbus RTU) communication (built-in option)

    pdf icon small Starvert iE5 Specifications

     


    Read more
  • iG5A

    Starvert iG5A

    0 out of 5
    • Powerful & compact sensorless vector control VFD
    • 1 phase 0.1~1.5kW (0.5~2.0HP), 200~230V
    • 3 phase 0.1~1.5kW (0.5~30HP), 200~230V
    • 3 phase 0.1~1.5kW (0.5~30HP), 380~480V
    • Selectable V/F, Sensorless vector control
    • Powerful torque at overall speed range
    • IP20 enclosure, UL type 1 (option)
    • Built-in RS484 (LS BUS/Modbus RTU) Communication

    pdf icon smallStarvert iG5A Catalogue (2.13 MB)

     


    Read more
  • starvert iH LS

    Starvert iH

    0 out of 5
    • Robust dual fated high power VFD
    • 3 phase 30~55kW (40~75HP), 200~230V
    • 3 phase 30~220kW (40~300HP), 380~480V
    • Space vector PWM technology
    • Low noise level (high performance DSP & IGBT)
    • Precise torque calculation through current control
    • 4~20mA analog output
    • 2 line 32 characters LCD display as standard
    • Built-in process PI
    • 150% starting torque
    • 2~10 khz carrier frequency

    pdf icon small   Starvert iH Catalogue (9.02 MB)
     


    Read more
  • Starvert iP5A LS

    Starvert iP5A

    0 out of 5
    • Fan & pump specialized VFD
    • 3 phase 5.5~30kW (7.5~40 HP), 200~230V
    • 3 phase 5.5~450kW (7.5~600 HP), 380~480V
    • Specialized functions for fan & pump :
      • Advanced PID control (Pre-PID, Dual PID)
      • Multi motor control function (up to 4 motors : 5.5~90kW)
    • Selectable V/F, sensorless vector control
    • Built-in RS485 (LS BUS) communications
    • Communication boards (optional)
      • Modbus RTU, Devicenet, Profibus-DP, Lonworks, Bacnet

    pdf icon smallSpecifications
     


    Read more
  • iS5

    Starvert iS5

    0 out of 5
    • Precise vector control standard VFD
    • 3 Phase 0.75~55kW (1~75HP), 200~230V
    • 3 Phase 0.75~75kW (1~100HP), 380~480V
    • Selectable V/F, sensorless, sensored rector control (optional)
    • Optimum acceleration & deceleration for a maximum torque
    • Multi-function 1/0 terminal
      • input : 27 functions / output : 21 functions
    • Communication options : Modbus RTU, Profibus-DP, Devicenet, RS485 (LS Bus), Fnet

    pdf icon small   Specifications

    pdf icon small   Starvert iS5 Catalogue (545.59 kB)

     


    Read more
  • iS7

    Starvert iS7

    0 out of 5
    • High torque performance and precise VFD
    • 3 Phase 0.75~22kW (1~30HP), 200~230V
    • 3 Phase 0.75~160kW (1~250HP), 380~480V
    • Constant torque/variable torque dual rating
    • Selectable V/F, sensorless, sensored vector control
    • Available IP54 enclosure 0.75~22kW (1~30HP) as built-in option
    • Built-in RS4 485 (LS BUS/Modbus RTU) Communication
    • Available EMC filter & DC reactor as built-in option EMC filter (0.75~22kW) / DC reactor (0.75~160kW)

    pdf icon smallStarvert iS7 Catalogue (2.85 MB)

     


    Read more
  • LS starvert iV5

    Starvert iV5

    0 out of 5
    • High duty full flux vector control VFD
    • 3 phase 2.2~37kW (3~50HP), 200~230V
    • 3 phase 2.2~375kW (3~500HP), 380~480V
    • Ultimate performance solution for system drive
    • Advanced speed & torque control
      • (200% instantaneous torque max 250%)
    • Precise speed & position synchronization operation
    • Static motor parameter auto tuning
    • Synchronous motor sensorless control (SPM & IPM motors)
    • Built-in dynamic braking transitor : 2.2~22kW (3~30HP)

    pdf icon smallStarvert iV5 Catalogue (48.86 MB)

     


    Read more

Showing all 9 results